Superior Double-Flame VD1824PR 24" Vent-Free Propane Gas Log Burner with Millivolt Control
The Superior Double-Flame VD1824PR is a 24-inch propane/LP gas log burner designed for approved Superior Double-Flame gas log configurations. It provides a variable input range of 25,000–36,000 BTU/hr and combines a dual-yellow-flame burner design with piezo ignition and a millivolt control system. The burner assembly is included; the decorative gas log set is required and sold separately.
Model
VD1824PR
Nominal Size
24"
Fuel
Propane / LP
Input
25,000–36,000 BTU/hr
Control
Millivolt
Ignition
Piezo
Manifold Pressure
8.0" W.C.
Gas Logs
Sold Separately
Important: Decorative Gas Logs Are Sold Separately
The VD1824PR includes the burner assembly only. A compatible approved 24" Superior Double-Flame decorative gas log set is required and must be purchased separately.
Propane / LP Only
The VD1824PR is configured specifically for propane/LP gas. Do not connect this burner to natural gas or another fuel type.
24" Propane Double-Flame Burner with Millivolt Control
The VD1824PR is designed for buyers who need a propane-configured Superior Double-Flame burner while retaining the flexibility to select the compatible decorative log set separately.
Its dual-yellow-flame burner design creates the flame presentation associated with Superior's Double-Flame series, while the variable input range allows operation between 25,000 and 36,000 BTU/hr.
The standing-pilot millivolt control system allows normal burner operation without household electrical power, while piezo ignition provides built-in pilot lighting.
Superior VD1824PR at a Glance
Brand
Superior Fireplaces
Product Type
Vent-Free Gas Log Burner
Input Rating
25,000–36,000 BTU/hr
Is the Superior VD1824PR Right for Your Fireplace?
Best For
- Installations with propane/LP fuel supply.
- Projects requiring the 24" VD1824PR burner configuration.
- Approved Superior Double-Flame decorative gas log sets.
- Compatible masonry fireplaces.
- Qualifying factory-built fireplace installations.
- Buyers wanting a standing-pilot millivolt burner.
- Users wanting compatible optional remote or wall controls.
- Vent-free installations with adequate combustion and ventilation air.
- Applications meeting all fireplace, mantel, wall, and flooring requirements.
Do Not Choose This Burner If
- Your fuel supply is natural gas.
- You need a separate 18" burner configuration.
- You expect the decorative gas logs to be included.
- Your fireplace does not meet the minimum 24" firebox requirements.
- You cannot meet required combustible clearances.
- You cannot provide adequate combustion and ventilation air.
- You intend to use an unapproved log set.
- You cannot provide the required external propane regulator.
Compatible Double-Flame Gas Log Sets
The burner and decorative log set are selected separately. The original product information identifies Double-Flame log styles including:
Golden Oak
Select an approved 24" configuration for the VD1824PR.
Townsend Bark
Verify the exact approved 24" log model before ordering.
Crescent Hill
Use only the manufacturer-approved configuration specified for this burner.
Century Oak
Confirm burner compatibility and required log placement before installation.
Do not mix gas logs. Use only the correct approved 24" log set for the VD1824PR. Do not combine logs from different models or sizes, and do not modify the required log arrangement.
Minimum Fireplace Size Requirements
For the manufacturer's 24-inch configuration, the fireplace must meet the following minimum firebox dimensions.
| Minimum Front Height |
17" |
| Minimum Depth |
13.5" |
| Minimum Front Width |
28" |
| Minimum Rear Width |
20.5" |
Minimum dimensions are only the first compatibility check. Mantel, side-wall, flooring, combustion-air, gas-supply, and other installation requirements must also be satisfied.
Propane / LP Gas Requirements
| Fuel Type |
Propane / LP |
| Input Rating |
25,000–36,000 BTU/hr |
| Manifold Pressure |
8.0" W.C. |
| Minimum Inlet Pressure |
11" W.C. |
| Maximum Inlet Pressure |
14" W.C. |
| Gas Connection |
3/8" NPT |
External propane regulator required: Superior's instructions specify an external regulator for propane/LP installations. The regulator is not supplied with the burner and must be properly selected and installed as part of the propane supply system.
Do not connect the VD1824PR to natural gas. Use only the fuel type specified for this model.
Millivolt Control System
The VD1824PR uses a millivolt control system with a standing pilot.
No Household Power Required
Normal burner operation does not require household electrical power.
Standing Pilot
The millivolt system operates with a standing-pilot configuration.
Piezo Ignition
Provides built-in pilot ignition.
Optional Remote Capability
Compatible remote-ready accessories may be used where identified by Superior.
Optional controls are not included. Verify the exact compatible remote or wall-control accessory before ordering.
Vent-Free Operation & Combustion Air
When operated vent-free, the VD1824PR uses air from the room for combustion.
The installation space must provide sufficient combustion and ventilation air according to Superior's procedures and applicable codes.
Vent-free does not mean ventilation-free. Do not install or operate the burner in a space that does not satisfy the required combustion-air provisions.
Vent-Free & Vented Operation
Vent-Free Operation
The VD1824PR is designed for vent-free use when all fireplace, clearance, combustion-air, gas-supply, and installation requirements are satisfied.
Vented Decorative Operation
Superior's instructions also provide for operation as a vented decorative appliance when applicable venting and permanent fireplace-damper-opening provisions are followed.
Installation requirements can differ by operating configuration. Do not assume that every vent-free clearance or requirement remains unchanged for vented decorative operation.
Installation & Clearance Requirements
The VD1824PR is designed for installation in an appropriate solid-fuel-burning masonry fireplace or qualifying factory-built fireplace when all manufacturer requirements are met.
Firebox Fit
Confirm the minimum 17" H × 13.5" D × 28" front W × 20.5" rear W firebox.
Side-Wall Clearance
Maintain all manufacturer-required clearance from combustible side-wall materials.
Mantel Clearance
Depends on mantel depth, position, and whether a hood is required.
Floor Clearance
Verify flooring and fireplace-elevation requirements before installation.
Combustion Air
Provide adequate combustion and ventilation air for vent-free operation.
Qualified Installation
Installation and service should be performed by a qualified service person.
Do not use one generic mantel or clearance dimension. Review the complete manufacturer clearance diagrams for the exact installation.
What's Included?
Included
- Superior Double-Flame VD1824PR burner assembly
Not Included
- Decorative gas log set — required and sold separately
- Optional remote-control accessories
- Optional wall controls
- External propane regulator
- Installation components not specifically supplied with the burner
Safety & Maintenance Considerations
Correct Fuel Only
Use propane/LP only.
Approved Logs Only
Do not use unapproved or mixed gas-log components.
Correct Log Placement
Follow Superior's exact log-positioning instructions.
Keep Burner Clean
Maintain burner ports and the control compartment free of lint, dust, and debris.
Inspect Regularly
Have the appliance inspected as required by the manufacturer.
Qualified Service
Service and repair should be performed by a qualified service person.
Additional cleaning may be required where carpet fibers, bedding material, pet hair, lint, or other debris can accumulate around the burner and controls.
Complete Superior VD1824PR Specifications
| Manufacturer |
Superior Fireplaces |
| Series |
Double-Flame |
| Model |
VD1824PR |
| Product Category |
Gas Log Burner |
| Product Type |
Vent-Free Gas Log Burner |
| Nominal Size |
24" |
| Fuel Type |
Propane / LP |
| Input Rating |
25,000–36,000 BTU/hr |
| Burner Design |
Dual Yellow Flame |
| Ignition |
Piezo |
| Control System |
Millivolt |
| Manifold Pressure |
8.0" W.C. |
| Minimum LP Inlet Pressure |
11" W.C. |
| Maximum LP Inlet Pressure |
14" W.C. |
| Gas Connection |
3/8" NPT |
| External LP Regulator |
Required – Not Included |
| Minimum Firebox Height |
17" |
| Minimum Firebox Depth |
13.5" |
| Minimum Firebox Front Width |
28" |
| Minimum Firebox Rear Width |
20.5" |
| Decorative Log Set Included |
No – Sold Separately |
| Remote Capability |
Compatible Optional Controls for Applicable Millivolt Configuration |
| Household Electrical Power Required for Burner |
No |
| Vent-Free Operation |
Supported When Manufacturer Requirements Are Satisfied |
| Vented Decorative Operation |
Supported When Installed According to Manufacturer Requirements |
Flame Authority Expert Recommendation
Choose the Superior VD1824PR when your fireplace project requires a 24-inch propane/LP Double-Flame burner with a standing-pilot millivolt control system and separately selected decorative gas logs.
Its 25,000–36,000 BTU/hr input range, dual-yellow-flame design, piezo ignition, millivolt control, propane-specific pressure requirements, and optional remote capability make it a practical burner platform for qualifying vent-free or vented decorative installations.
The most important buying step is confirming the propane fuel supply, required external regulator, 24" configuration, minimum fireplace opening, compatible log set, combustible clearances, combustion-air availability, and installation location before ordering.
Official Manufacturer Resource
Installation & Operation Instructions
Manufacturer fireplace dimensions, combustion-air requirements, propane supply and regulator requirements, gas connections, clearances, log-placement guidance, controls, vented-operation provisions, maintenance, troubleshooting, and safety information.
Superior VD1824PR FAQs
Is the Superior VD1824PR propane or natural gas?
The VD1824PR is configured for propane/LP gas. Do not connect this model to natural gas or another fuel type.
Is the Superior VD1824PR an 18" or 24" burner?
The VD1824PR is the 24-inch propane/LP configuration.
Are gas logs included with the Superior VD1824PR?
No. The burner assembly is included, but a compatible approved 24" Double-Flame gas log set is required and sold separately.
How many BTUs does the Superior VD1824PR produce?
The burner has a variable input rating of 25,000 to 36,000 BTU/hr.
What size fireplace is required for the VD1824PR?
The 24" configuration requires at least 17" height, 13.5" depth, 28" front width, and 20.5" rear width.
What propane pressure does the VD1824PR require?
The supplied specifications identify 8.0" W.C. manifold pressure with 11" W.C. minimum and 14" W.C. maximum inlet pressure.
Does the VD1824PR require an external propane regulator?
Yes. Superior's instructions specify an external regulator for propane/LP installations. It is not supplied with the burner.
Does the Superior VD1824PR require household electricity?
No. The burner uses a millivolt standing-pilot system, so household electrical power is not required for normal burner operation.
Can the Superior VD1824PR use a remote control?
Compatible optional remote-ready controls may be used with the applicable millivolt configuration. A remote control is not included.
Does the VD1824PR require combustion air even when operated vent-free?
Yes. Vent-free operation still requires adequate combustion and ventilation air according to the manufacturer instructions and applicable codes.
Can the VD1824PR be operated as a vented decorative appliance?
Yes. Superior's instructions provide for vented decorative operation when the applicable venting and permanent damper-opening requirements are followed.
Can I use any 24" gas log set with the VD1824PR?
No. Use only an approved Superior Double-Flame 24" log set intended for the VD1824PR configuration.
Before You Order
Confirm Before Purchase
- You specifically need the Superior VD1824PR.
- Your fuel supply is propane/LP.
- You require the 24" burner configuration.
- You have selected an approved 24" Superior Double-Flame gas log set.
- Your fireplace measures at least 17" H × 13.5" D × 28" front W × 20.5" rear W.
- You can maintain all required fireplace, side-wall, mantel, and floor clearances.
- The room provides adequate combustion and ventilation air for vent-free use.
- Your propane supply can meet the 11"–14" W.C. inlet-pressure requirement.
- You have planned for the required external propane regulator.
- You understand that decorative gas logs and optional controls are sold separately.
Do Not Assume
- That natural gas can be used with the VD1824PR.
- That the VD1824PR is an 18" burner.
- That decorative logs are included.
- That any 24" gas log set is compatible.
- That an external propane regulator is included.
- That nominal burner size alone establishes fireplace compatibility.
- That vent-free operation eliminates combustion-air requirements.
- That vented and vent-free installation requirements are identical.
- That optional remote or wall controls are included.
Final planning check: Use the Superior Installation & Operation Instructions to verify the exact 24" log configuration, propane supply, external regulator, firebox dimensions, combustible clearances, combustion air, gas pressure, log placement, optional controls, vented-operation requirements, and final installation before ordering.